Tank agitators in mineral processing: impellers and flow patterns, baffles, solids suspension, gearboxes and keeping agitators running
Tank agitators in mineral processing: the motor, gearbox, overhung shaft, impellers and baffles, hydrofoil, pitched blade, radial and anchor impellers and the flow each makes, baffles and just suspended speed, leach, conditioning, holding and reagent duties, the common problems including sanded tanks after a power outage, and maintenance from rounds to impeller inspection. With a drawing of an agitated tank.

Key takeaways
- An agitator is a motor, gearbox, overhung shaft and one or more impellers, with baffles on the tank wall doing half the work.
- Hydrofoil impellers suit most mineral slurry tanks. They move the most slurry for the power and keep solids off the floor.
- Without baffles the slurry spins as a whole, solids settle and the shaft is loaded unevenly.
- The worst agitator event is usually a sanded tank after a power outage. Plan the restart before it happens.
- Gearbox oil, bolt torque and impeller wear are the main maintenance tasks. Motor current is a free indicator of impeller condition.
A train of leach tanks loses power for forty minutes. When it comes back, three agitators restart and the fourth trips on overload, then trips again. The solids have settled around its impeller, and the next hours go into air lancing, diluting and nursing a gearbox that has just taken several overload starts.
This guide covers tank agitators in mineral processing: the parts, impeller types and flow patterns, baffles and solids suspension, the common duties, the problems that stop them, and maintenance. It sits beside the guides to thickeners, industrial gearbox maintenance and slurry pumps. The drawing is schematic.
Parts of an agitator
A top entry agitator hangs from a bridge or mounting above the tank. The motor drives a gearbox, the gearbox output bearings carry an overhung shaft, and the impellers turn near the bottom of the tank with no bearing below them. The impeller pushes the flow, the baffles turn it, and the shape of the tank floor and the impeller's height off it decide where solids settle.
| Part | What it does | What to watch |
|---|---|---|
| Drive motor | Turns the gearbox, fixed speed or on a variable speed drive | Current draw tells you how hard the impeller is working |
| Gearbox | Reduces motor speed to impeller speed and carries the shaft loads | Oil condition, temperature, noise, and the output bearings that carry the shaft |
| Bridge or mounting | Holds the drive above the tank and takes the reaction forces | Bolts and welds, because flow forces load the mounting with every turn |
| Shaft | Hangs from the gearbox, usually with no bearing in the tank | Straightness and runout. A long overhung shaft bends with uneven flow |
| Impellers | Move the slurry, one or more on the shaft | Blade wear and lost rubber lining change the flow and the load |
| Baffles | Vertical strips on the tank wall that stop the slurry swirling as a whole | Worn or missing baffles let the slurry spin and solids settle |
Impellers and flow patterns
Axial impellers pump the slurry down the shaft, across the floor, up the walls and back to the impeller, which is the flow that lifts solids. Radial impellers throw slurry outward to the wall and create high shear around the blades. For solids suspension, the impeller diameter is often about a third to a half of the tank diameter, and the impeller sits between about a sixth and a third of the tank diameter off the floor. Tall tanks carry a second impeller higher on the shaft.
| Impeller | Flow pattern | Used for |
|---|---|---|
| Hydrofoil | Axial, pumping down the shaft and up the walls with little shear | Solids suspension in large leach and slurry tanks, for the least power per flow |
| Pitched blade turbine | Axial and radial, a mixed flow | General mixing and suspension, robust and simple |
| Radial flat blade (Rushton type) | Radial, throwing slurry to the wall with high shear | Gas dispersion and fast reactions, high power for the flow |
| Anchor or helical ribbon | Sweeps close to the tank wall at low speed | Thick, viscous mixtures that turbines cannot move |
Baffles and solids suspension
Four baffles, each about one twelfth of the tank diameter wide, are the usual arrangement. They stop the slurry rotating with the impeller and turn the swirl into top to bottom flow. A small gap between the baffles and the wall stops solids building up behind them.
The design point for most slurry tanks is just suspended speed, where no solids stay on the floor. Below it, solids build up in fillets at the floor corners and centre, reducing the tank's working volume and residence time. Above it, power rises steeply for little gain. Wear changes all of this, so a worn impeller that once suspended the solids may no longer do so.
Agitator duties in mineral processing
Each duty asks something different of the agitator. Leach tanks need suspension and gas dispersion over long residence times, reagent tanks need gentle mixing, and holding tanks mainly need to keep solids off the floor so the pumps downstream see a steady feed.
| Duty | What the agitator must do | Notes |
|---|---|---|
| Leach and carbon in leach tanks | Keep solids and carbon suspended and air or oxygen dispersed over long residence times | Several tanks in series, so an outage backs up the whole train |
| Flotation conditioning | Mix reagents into slurry before flotation | Short residence time, a well mixed tank matters more than suspension |
| Slurry and thickener underflow holding | Keep solids off the floor until the slurry is pumped on | Sanding risk is high when the agitator stops |
| Reagent and flocculant make-up | Dissolve and mix reagents without damaging them | Flocculant needs gentle mixing, high shear breaks the long chains |
| Neutralisation and lime | Mix lime or acid into slurry and keep the pH even | Scale builds on impellers and baffles |
Common agitator problems
Agitators run continuously for years and often fail without much warning. The shaft and impeller carry uneven, cyclic loads from the flow, and the gearbox output bearings take them. Watching motor current, gearbox temperature and noise on rounds catches most problems early, and oil analysis shows gearbox wear before it becomes a failure.
| Problem | What you see | Likely cause |
|---|---|---|
| Gearbox bearing or gear failure | Noise, heat, metal in the oil | Overload from a sanded start, poor lubrication, shaft loads above the rating |
| Shaft vibration | Swinging shaft, cracking at the mounting | Worn or uneven impeller blades, missing baffles, liquid level near the impeller |
| Worn impellers | Lower current draw, solids settling, falling recovery | Abrasive slurry, worn rubber lining |
| Sanded tank | The agitator will not start or trips on overload after a stop | Solids settled during a power outage or a long stop |
| Loose hub or coupling bolts | Knocking, a shaft that moves at the coupling | Cyclic loads loosen bolts that are not checked and torqued |
| Scale and build-up | Rising power draw, out of balance shaft | Lime and other reagents scaling the blades and baffles |
Write the restart procedure for a settled tank before the next power outage, not during it.
Maintaining agitators
Most agitator maintenance happens from the top of the tank. Impellers and baffles can only be inspected when the tank is drained, which makes that a confined space entry and usually a shutdown task. Agitators whose loss stops the circuit warrant critical spares, usually a gearbox or an impeller set.
| Task | What it involves | When |
|---|---|---|
| Rounds checks | Noise, gearbox temperature, oil level, leaks, motor current against normal | Every shift |
| Gearbox oil | Sample for wear metals and water, change on condition | Quarterly sample, change as the maker says or on results |
| Bolt checks | Torque the coupling, hub and mounting bolts to the set values | At set intervals and after any work on the drive |
| Impeller and baffle inspection | Measure blade wear and lining, check baffles and the shaft | When the tank is drained, under a confined space permit |
| Restart after a stop | Follow a set procedure to restart a settled tank, with air lances or dilution if needed | After any outage longer than the slurry takes to settle |
| Spares | Hold a spare gearbox or impeller set for the agitators whose loss stops the train | Decided by criticality |
Common mistakes
- No written restart procedure for a settled tank.
- Running with worn or missing baffles.
- Ignoring a falling motor current, which often means worn impellers.
- Coupling and hub bolts never rechecked after installation.
- Gearbox oil changed on the calendar without sampling.
- Running with the liquid level near an impeller, which loads the shaft and draws in air.
Common questions
What does an agitator do in a tank?
An agitator keeps the contents of a tank moving so they stay mixed and solids stay suspended. In mineral processing it keeps slurry off the tank floor, mixes in reagents, disperses air or oxygen, and keeps carbon suspended in carbon in leach tanks. It is made up of a drive motor, a gearbox, a shaft hanging into the tank and one or more impellers, with baffles fixed to the tank wall.
What types of impeller are used in agitators?
The main types are hydrofoil impellers, which pump axially with little shear and suit solids suspension, pitched blade turbines, which give a mixed axial and radial flow, and radial flat blade turbines, which give high shear for gas dispersion. Anchors and helical ribbons are used for thick, viscous mixtures. Most large slurry tanks in mineral processing use hydrofoils.
Why do agitator tanks have baffles?
Baffles are vertical strips fixed to the tank wall, usually four, each about one twelfth of the tank diameter wide. Without them, the impeller sets the whole tank swirling, a vortex forms, there is little top to bottom flow, and solids collect in the middle of the floor. Baffles turn the swirl into vertical flow, which is what keeps solids suspended.
What is a sanded tank?
A tank is sanded when the solids settle into a dense bed around the impeller after the agitator stops, usually during a power outage. The agitator may then trip on overload or damage its gearbox trying to start. Sites deal with it by restarting quickly after short stops, using a set restart procedure, air lances or dilution water to loosen the bed, and in some cases a variable speed drive to start slowly.
What is just suspended speed?
Just suspended speed is the impeller speed at which no particles rest on the tank floor for more than a moment. It is the usual design point for solids suspension, because running faster costs much more power for little gain in most duties. It depends on the particle size and density, the solids concentration, the impeller type and size, and how far the impeller sits off the floor.
Key terms
Plain-language definitions from our glossary for the concepts this article leans on.
Standards and further reading
Related case studies and tools
- Reliability engineering and asset strategy program (case study)
Related reading
Running plant like this?
Enco helps the teams that run and maintain it, with maintenance strategy, asset data and planning, condition monitoring and reporting software, and engineering studies. See the work we have delivered, or tell us what you are dealing with.